| | High Level Instrument Disinfectant
Active Ingredients:
15% Isopropylol; 0.5% QAC Blend;
0.5% Tertiary Amine; 0.8% pH Buffer;
0.8% Corrosion Inhibitor; 0.3% Surfactant
Product characteristics:
Ready-to-use; Unfragranced;
Non-corrosive; Non-toxic; Non-staining
Non-caustic; Biodegradeable
Recommended Uses:
Disinfection of pre-cleaned
thermo-sensitive instruments.
Disinfection of pre-cleaned
instruments where a functional calibrated
autoclave is unavailable.
Where access to an approved, regularly maintained and tested autoclave is available, the autoclave should always be considered the primary means of sterilisation.
Instructions for use:
Decant the required amount of Cold Sterilant into a clean, dry, covered stainless steel or HDPE receptacle. Completely immerse thoroughly disassembled, pre-cleaned, rinsed & dried instruments / devices in the liquid, ensuring that any hinges or joints are in the open position. Allow a contact time as per your desired efficacy – see below efficacy table. Remove the instruments / devices from the liquid using sterile forceps, and follow the post-sterilisation procedure of the facility. Tray-life of the liquid should be tested weekly using M.E.C. strips. The product should have a tray-life of between 21 & 28 days, should the strips prove a shorter life, check your instrument cleaning process. For best results, replace the liquid every 28 days, or as soon as an MEC Test Strip reads less than 1000ppm active ingredient, or immediately if any change in liquid colour occurs.
Pre-Requirements:
Latex or nitrile gloves for sensitive skin, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.
Product Description:
- Available sizes: 20L, 5L, 1L
- Dilution Factor: Ready to use
- Physical Form: Translucent blue liquid
- Odour: Mild chemical fragrance
- pH: 7-8
- Tray Life: 21-28 days (MEC Test Strips available)
- Product Risk Classification: C / IIb
- GMDN Code: 47631
- GMDN Descriptor: Medical Device Disinfectant
- NRCS Reg. no: CT29GNR529/242056/040/497
- Incompatibilities: Anionic detergents, Natural Soaps, Strong oxidisers
| | |
STESC2 |
| | |
| | High Level Instrument Disinfectant
Active Ingredients:
15% Isopropylol; 0.5% QAC Blend;
0.5% Tertiary Amine; 0.8% pH Buffer;
0.8% Corrosion Inhibitor; 0.3% Surfactant
Product characteristics:
Ready-to-use; Unfragranced;
Non-corrosive; Non-toxic; Non-staining
Non-caustic; Biodegradeable
Recommended Uses:
Disinfection of pre-cleaned thermo-sensitive instruments. Disinfection of pre-cleaned
instruments where a functional calibrated autoclave is unavailable.
Instructions for use:
Decant the required amount of Cold Sterilant into a clean, dry, covered stainless steel or HDPE receptacle. Completely immerse thoroughly disassembled, pre-cleaned, rinsed & dried instruments / devices in the liquid, ensuring that any hinges or joints are in the open position. Allow a contact time as per your desired efficacy – see below efficacy table. Remove the instruments / devices from the liquid using sterile forceps, and follow the post-sterilisation procedure of the facility. Tray-life of the liquid should be tested weekly using M.E.C. strips. The product should have a tray-life of between 21 & 28 days, should the strips prove a shorter life, check your instrument cleaning process. For best results, replace the liquid every 28 days, or as soon as an MEC Test Strip reads less than 1000ppm active ingredient, or immediately if any change in liquid colour occurs.
Pre-Requirements:
Latex or nitrile gloves for sensitive skin, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.
Product Description:
Available sizes: 20L, 5L, 1L
Dilution Factor: Ready to use
Physical Form: Translucent blue liquid
Odour: Mild chemical fragrance
pH: 7-8
Tray Life: 21-28 days (MEC Test Strips available)
Product Risk Classification: C / IIb
GMDN Code: 47631
GMDN Descriptor: Medical Device Disinfectant
NRCS Reg. no.: ACT29GNR529/242056/040/497
Medical Device Reg. No.: Awaiting Class Registration Call-up
Incompatibilities: Anionic detergents, Natural Soaps, Strong oxidisers
| | |
STEST2 |
| | |
| | In-Situ Vacuum System Line Detergent-Disinfectant
Active Ingredients:
4.25% 5th Generation Quaternary Ammonium Compound blend
Product characteristics:
Super-concentrated; Unfragranced; Non-corrosive; Non-toxic; Non-staining Non-caustic; Biodegradeable
Recommended Uses:
In-situ terminal cleaning, disinfection & odour control of healthcare suction systems.Odour control & unblocking of inground drains which contain congealed organic matter. Cleaning & disinfection of hard to reach, non-sensitive areas in air conditioning systems.
Instructions for use:
Shake well before use. Dilute Disinfecting Suction Cleaner as per below efficacy table, where 1% equals 10mL product per 1L of water or 1 dosing pump with 2.5L of water.. Pour or aspirate the diluted solution into the system. Allow the contact time of your required efficacy before flushing the system. For badly maintained systems (or the initial 4 uses), leave the solution in the system overnight, flushing the system the following morning. Dilute only enough for immediate single use – if unused, discard within 7 days of dilution. Repeat daily.
Pre-Requirements:
Latex gloves & chemical splash goggles are required when handling or discarding the product.
Product Description:
Available sizes: 20L, 5L, 1L, 1L Dosing Bottle
Dilution Factor: 1:100 or 1% (10mL per L)
Physical Form: Translucent pink-orange liquid
Odour: Mild chemical smell
pH: Concentrate and dilute: 12-13
Risk Classification: B / IIa
GMDN Code: 47631
GMDN Descriptor: Medical Device Disinfectant
NRCS Reg. no.: ACT29GNR529/242056/040/496
Medical Device Reg. No.: Awaiting Class Registration Call-up
Incompatibility: Anionic detergents, Strong oxidisers
| | |
STESV2D |
| | |
| | HealthCare Surface & Equipment Disinfecting Wipes
Active Ingredients:
0.075% Fifth generation QAC Blend;
0.5% Preservative.
Product characteristics:
Vacuum-impregnated; Unfragranced;
Non-corrosive; Non-toxic; Non-staining
Non-caustic; Convenient
Recommended Uses:
Healthcare surface disinfection.
Medical Device disinfection.
Disinfection of high-touch items, especially where the use of a spray disinfectant is inadvisable.
Instructions for use:
To begin: Remove the lid & remove the sealed inner bag. Ensure that the leading wipe is at the top, cut open the bag & place it back in the tub. Open the flap in the lid & pull the leading wipe slowly through the hole. Replace the lid onto the tub and the wipes are ready to use. When needed: Simply pull out a wipe, tear it off on the perforation and use. Best results are achieved when used on a visibly clean, dry surface. Allow the contact time of your required efficacy, (as per the efficacy table below right), before using the surface again. Repeat as often as required by your Infection Control protocol (suggested protocols available on request). Always ensure that the flap is tightly shut after use to prevent drying out of the wipes. Wipe material is not efficiently biodegradable.
Pre-Requirements:
None strictly necessary, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.
Product Description:
Available sizes: 100s Tub; 100s Refill (Wipe Size: 200mm x 140mm)
Dilution Factor: Not applicable - pre-impregnated wipe
Physical Form: White, non-woven wipe
Odour: Mild chemical fragrance
pH: 5-6.5
Risk Classification: B / II
GMDN Code: 58077
GMDN Descriptor:
Medical Device Disinfection Wipe
NRCS Reg. no.: ACT5GNR529/242613/040/0256
Medical Device Reg. No.: Pending
Incompatibility: Anionic detergents, Natural Soaps, Strong oxidisers
| | |
STESW2 |
| | |
| |
HealthCare Surface & Equipment Disinfecting Wipes
Active Ingredients:
0.075% Fifth generation QAC Blend;
0.5% Preservative.
Product characteristics:
Vacuum-impregnated; Unfragranced;
Non-corrosive; Non-toxic; Non-staining
Non-caustic; Convenient
Recommended Uses:
Healthcare surface disinfection.
Medical Device disinfection.
Disinfection of high-touch items, especially where the use of a spray disinfectant is inadvisable.
Instructions for use:
To begin: Remove the lid & remove the sealed inner bag. Ensure that the leading wipe is at the top, cut open the bag & place it back in the tub. Open the flap in the lid & pull the leading wipe slowly through the hole. Replace the lid onto the tub and the wipes are ready to use. When needed: Simply pull out a wipe, tear it off on the perforation and use. Best results are achieved when used on a visibly clean, dry surface. Allow the contact time of your required efficacy, (as per the efficacy table below right), before using the surface again. Repeat as often as required by your Infection Control protocol (suggested protocols available on request). Always ensure that the flap is tightly shut after use to prevent drying out of the wipes. Wipe material is not efficiently biodegradable.
Pre-Requirements:
None strictly necessary, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.
Product Description:
Available sizes: 100s Tub; 100s Refill (Wipe Size: 200mm x 140mm)
Dilution Factor: Not applicable - pre-impregnated wipe
Physical Form: White, non-woven wipe
Odour: Mild chemical fragrance
pH: 5-6.5
Risk Classification: B / II
GMDN Code: 58077
GMDN Descriptor:
Medical Device Disinfection Wipe
NRCS Reg. no.: ACT5GNR529/242613/040/0256
Medical Device Reg. No.: Pending
Incompatibility: Anionic detergents, Natural Soaps, Strong oxidisers
| | |
STESW4 |
| | |
| | | | |
STESH3 |
| | |
| | | | |
STESW7 |
| | |
| | PrimeSafe Alcohol Surface Spray
Active Ingredients:
PrimeSafe Alcohol Surface Spray contains 70% v/v Isopropylol; 30% Inert Ingredients
Product characteristics:
User friendly, stable, Efficacy first, Safe, Convenient, Versatile
Recommended Uses:
Clinical Surface disinfection. Laboratory surface and equipment disinfection. Disinfection of items where a water-based product cannot be used.
Instructions for use:
Thoroughly pre-clean and rinse the surface wherever possible. Spray PrimeSafe Alcohol Surface Spray uniformly over the surface from a distance of about 30cm away, ensuring that the surface is completely covered. Allow the surface to dry naturally, or for a minimum contact time of 1 minute, prior to using the surface again.
Pre-Requirements:
Latex gloves for sensitive skin, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.
Product Description:
Available sizes: 20L, 5L, 1L Trigger Spray
Dilution Factor: Ready to use
Physical Form: Translucent liquid
Odour: Mild alcohol odour
pH: 6.5-7.5
Risk Classification: B / IIa
GMDN Code: 47631
GMDN Descriptor: Medical Device Disinfectant
NRCS Reg. no.: ACT5GNR529/242613/090/0781
Medical Device Reg. No.: Awaiting Registration Call-up
Incompatibility: Do not mix with other chemicals
| | |
PRIPASS2 |
| | |
| | High-Level Instrument Disinfectant
Active Ingredients:
0.575% Ortho-pthalaldehyde;
0.4% Rust Inhibitor; 2% Surfactant; 97.025% Inert Ingredients
Product characteristics:
Ready-to -use; Locally Made;
Non-corrosive; Non-staining Non-caustic; Biodegradeable
Recommended Uses:
Sterilisation / disinfection of pre-cleaned thermo-sensitive instruments. Sterilisation / disinfection of pre-cleaned instruments where a functional calibrated autoclave is unavailable.
Instructions for use:
Decant the required amount of OPA into a clean, dry, covered stainless steel or HDPE receptacle. Completely immerse thoroughly disassembled, pre-cleaned, rinsed & dried instruments / devices in the liquid, ensuring that any hinges or joints are in the open position. Allow a contact time as per your desired efficacy – see below efficacy table. Remove the instruments / devices from the liquid using sterile forceps, and follow the post-sterilisation procedure of the facility. Tray-life of the liquid should be tested weekly using M.E.C. strips. The product should have a tray-life of between 14 & 21 days, should the strips prove a shorter life, check your instrument cleaning process. For best results, replace the liquid every 14 days, or as soon as an MEC Test Strip reads less than 0.5% active ingredient, or immediately if any change in liquid colour occurs.
Pre-Requirements:
Latex or nitrile gloves, protective aprons and chemical splash goggles. Use only in well-ventilated areas.
Product Description:
Available sizes: 20L, 5L, 1L
Dilution Factor: Ready to use
Physical Form: Pale yellow liquid
Odour: Chemical Odour
pH: 7-9
Risk Classification: C / IIb
GMDN Code: 40579
GMDN Descriptor: Gluteraldehyde Device Sterilant
NRCS Reg. no.: Pending
Medical Device Reg. No.: Awaiting Registration Call-up
Incompatibility: Do not mix with other chemicals
| | |
PRIPOP2 |
| | |
| | Thryve Clean Hand Sanitizer
Intended Use
Hand sanitiser for the disinfection of hands and surfaces.
Instructions Per Use
Spray hands or surfaces liberally and let air dry.
Ingredients
- Electrolysed saline solution - (HOCI +250ppm)
- pH 5-7
- This product contains no alcohol
Precautions
- Sensitivity to HOCI
- For external use only
Storage
- Store below 25°C.
- Keep out of direct sunlight.
- Recommended to use within 30 days after opening.
| | |
IVC201 |
| | |
| | Thryve Clean Hand Sanitizer
Intended Use
Hand sanitiser for the disinfection of hands and surfaces.
Instructions Per Use
Spray hands or surfaces liberally and let air dry.
Ingredients
- Electrolysed saline solution - (HOCI +250ppm)
- pH 5-7
- This product contains no alcohol
Precautions
- Sensitivity to HOCI
- For external use only
Storage
- Store below 25°C.
- Keep out of direct sunlight.
- Recommended to use within 30 days after opening.
| | |
IVC200 |
| | |
| | IVOClean Disinfectant (HOCI) 2,5L
Indications
For the decontamination and removal of biofilm in dental unit water lines (DUWL). IvoClean Dental Unit Water Line Disinfectant has a wide antimicrobial action against bacteria, viruses, fungi and spores.
- Eco-friendly
- Bio-degradable
- Non-irritant
- Non-toxic
- Hypoallergenic
Dosage & Directions
Dilute 1 part IvoClean Dental Unit Water Line Disinfectant to 9 parts clean water into DUWL container to obtain 10% concentration.
Ingredients
- Electrolysed saline solution
- (HOCI +500ppm)
- pH 5-7
- This product contains NO HARMFUL CHEMICALS or ALCOHOL.
Precautions
- IvoClean Dental Unit Water Line Disinfectant is safe for all areas when used at the correct dilution.
- Keep out of reach of children.
- Avoid eye contact. In the event of accidental eye contact, hold eye open and rinse gently with water.
- Avoid prolonged contact with metal parts at full concentration.
- Use only as instructed.
Contraindications
- IvoClean DUWL Disinfectant is not compatible with any chemical.
- Use only as instructed.
| | |
IVC105 |
| | |
| | IvoClean Dental Unit Water Line Disinfectant (GOCI) 2,5L
Indications
A disfectant suitable for the general disinfection of equipment and surfaces in both household and industrial sectors.
- Eco-friendly
- Bio-degradable
- Non-irritant
- Non-toxic
- Hypoallergenic
Dosage & Directions
To be used after cleaning with a suitable detergent. A HIGH LEVEL disinfectant spray for all surfaces, including areas for food preparation.
- Dilute 1 part IvoClean Disinfectant to 4 parts water. - Spray liberally over the surface to be disinfected and let dry.
Ingredients
- Electrolysed saline solution
- (HOCI +500ppm)
- pH 5-7
- This product contains NO HARMFUL CHEMICALS or ALCOHOL
Precautions
- IvoClean Disinfectant is safe for all areas when used at the correct dilution.
- Keep out of reach of children.
- Avoid eye contact. In the event of accidental eye contact, hold eye open and rinse gently with water.
- Avoid prolonged contact with metal parts at full concentration.
Contraindications
- IvoClean Disinfectant is not compatible with any chemical. - Use only as instructed.
| | |
IVC106 |
| | |