7 Results

IVOdentIVOhealthProduct Infoadditional 1additional 2Item number:QtyPrice

High Level Instrument Disinfectant

Active Ingredients:

15% Isopropylol; 0.5% QAC Blend;

0.5% Tertiary Amine; 0.8% pH Buffer;

0.8% Corrosion Inhibitor; 0.3% Surfactant

 

Product characteristics:

Ready-to-use; Unfragranced;

Non-corrosive; Non-toxic; Non-staining

Non-caustic; Biodegradeable

 

Recommended Uses:

Disinfection of pre-cleaned

thermo-sensitive instruments.

Disinfection of pre-cleaned

instruments where a functional calibrated

autoclave is unavailable.

Where access to an approved, regularly maintained and tested autoclave is available, the autoclave should always be considered the primary means of sterilisation.

 

Instructions for use:

Decant the required amount of Cold Sterilant into a clean, dry, covered stainless steel or HDPE receptacle. Completely immerse thoroughly disassembled, pre-cleaned, rinsed & dried instruments / devices in the liquid, ensuring that any hinges or joints are in the open position. Allow a contact time as per your desired efficacy – see below efficacy table. Remove the instruments / devices from the liquid using sterile forceps, and follow the post-sterilisation procedure of the facility. Tray-life of the liquid should be tested weekly using M.E.C. strips. The product should have a tray-life of between 21 & 28 days, should the strips prove a shorter life, check your instrument cleaning process. For best results, replace the liquid every 28 days, or as soon as an MEC Test Strip reads less than 1000ppm active ingredient, or immediately if any change in liquid colour occurs.

 

Pre-Requirements:

Latex or nitrile gloves for sensitive skin, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.

 

Product Description:

  • Available sizes: 20L, 5L, 1L
  • Dilution Factor: Ready to use
  • Physical Form: Translucent blue liquid
  • Odour: Mild chemical fragrance
  • pH: 7-8
  • Tray Life: 21-28 days (MEC Test Strips available)
  • Product Risk Classification: C / IIb
  • GMDN Code: 47631
  • GMDN Descriptor: Medical Device Disinfectant
  • NRCS Reg. no: CT29GNR529/242056/040/497
  • Incompatibilities: Anionic detergents, Natural Soaps, Strong oxidisers
STESC2

High Level Instrument Disinfectant

Active Ingredients:

15% Isopropylol; 0.5% QAC Blend;

0.5% Tertiary Amine; 0.8% pH Buffer;

0.8% Corrosion Inhibitor; 0.3% Surfactant

 

Product characteristics:

Ready-to-use; Unfragranced;

Non-corrosive; Non-toxic; Non-staining

Non-caustic; Biodegradeable

 

Recommended Uses:

Disinfection of pre-cleaned thermo-sensitive instruments. Disinfection of pre-cleaned

instruments where a functional calibrated autoclave is unavailable.

 

Instructions for use:

Decant the required amount of Cold Sterilant into a clean, dry, covered stainless steel or HDPE receptacle. Completely immerse thoroughly disassembled, pre-cleaned, rinsed & dried instruments / devices in the liquid, ensuring that any hinges or joints are in the open position. Allow a contact time as per your desired efficacy – see below efficacy table. Remove the instruments / devices from the liquid using sterile forceps, and follow the post-sterilisation procedure of the facility. Tray-life of the liquid should be tested weekly using M.E.C. strips. The product should have a tray-life of between 21 & 28 days, should the strips prove a shorter life, check your instrument cleaning process. For best results, replace the liquid every 28 days, or as soon as an MEC Test Strip reads less than 1000ppm active ingredient, or immediately if any change in liquid colour occurs.

 

Pre-Requirements:

Latex or nitrile gloves for sensitive skin, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.

 

Product Description:

Available sizes: 20L, 5L, 1L

Dilution Factor: Ready to use

Physical Form: Translucent blue liquid

Odour: Mild chemical fragrance

pH: 7-8

Tray Life: 21-28 days (MEC Test Strips available)

Product Risk Classification: C / IIb

GMDN Code: 47631

GMDN Descriptor: Medical Device Disinfectant

NRCS Reg. no.: ACT29GNR529/242056/040/497

Medical Device Reg. No.: Awaiting Class Registration Call-up

Incompatibilities: Anionic detergents, Natural Soaps, Strong oxidisers

STEST2

In-Situ Vacuum System Line Detergent-Disinfectant

Active Ingredients:

4.25% 5th Generation Quaternary Ammonium Compound blend

 

Product characteristics:

Super-concentrated; Unfragranced; Non-corrosive; Non-toxic; Non-staining Non-caustic; Biodegradeable

 

Recommended Uses:

In-situ terminal cleaning, disinfection & odour control of healthcare suction systems.Odour control & unblocking of inground drains which contain congealed organic matter. Cleaning & disinfection of hard to reach, non-sensitive areas in air conditioning systems.

 

Instructions for use:

Shake well before use. Dilute Disinfecting Suction Cleaner as per below efficacy table, where 1% equals 10mL product per 1L of water or 1 dosing pump with 2.5L of water.. Pour or aspirate the diluted solution into the system. Allow the contact time of your required efficacy before flushing the system. For badly maintained systems (or the initial 4 uses), leave the solution in the system overnight, flushing the system the following morning. Dilute only enough for immediate single use – if unused, discard within 7 days of dilution. Repeat daily.

 

Pre-Requirements:

Latex gloves & chemical splash goggles are required when handling or discarding the product.

 

Product Description:

Available sizes: 20L, 5L, 1L, 1L Dosing Bottle

Dilution Factor: 1:100 or 1% (10mL per L)

Physical Form: Translucent pink-orange liquid

Odour: Mild chemical smell

pH: Concentrate and dilute: 12-13

Risk Classification: B / IIa

GMDN Code: 47631

GMDN Descriptor: Medical Device Disinfectant

NRCS Reg. no.: ACT29GNR529/242056/040/496

Medical Device Reg. No.: Awaiting Class Registration Call-up

Incompatibility: Anionic detergents, Strong oxidisers

STESV2D

HealthCare Surface & Equipment Disinfecting Wipes

Active Ingredients:

0.075% Fifth generation QAC Blend;

0.5% Preservative.

 

Product characteristics:

Vacuum-impregnated; Unfragranced;

Non-corrosive; Non-toxic; Non-staining

Non-caustic; Convenient

 

Recommended Uses:

Healthcare surface disinfection.

Medical Device disinfection.

Disinfection of high-touch items, especially where the use of a spray disinfectant is inadvisable.

 

Instructions for use:

To begin: Remove the lid & remove the sealed in­ner bag. Ensure that the leading wipe is at the top, cut open the bag & place it back in the tub. Open the flap in the lid & pull the leading wipe slowly through the hole. Replace the lid onto the tub and the wipes are ready to use.  When needed: Simply pull out a wipe, tear it off on the perforation and use. Best results are achieved when used on a visibly clean, dry surface. Allow the contact time of your required efficacy, (as per the efficacy table below right), before using the surface again. Repeat as often as required by your Infection Control protocol (suggested proto­cols available on request). Always ensure that the flap is tightly shut after use to prevent drying out of the wipes. Wipe material is not efficiently biodegradable.

 

Pre-Requirements:

None strictly necessary, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.

Product Description:

Available sizes: 100s Tub; 100s Refill (Wipe Size: 200mm x 140mm)

Dilution Factor: Not applicable - pre-impregnated wipe

Physical Form: White, non-woven wipe

Odour: Mild chemical fragrance

pH: 5-6.5

Risk Classification: B / II

GMDN Code: 58077

GMDN Descriptor:

Medical Device Disinfection Wipe

NRCS Reg. no.: ACT5GNR529/242613/040/0256

Medical Device Reg. No.: Pending

Incompatibility: Anionic detergents, Natural Soaps, Strong oxidisers

STESW2

HealthCare Surface & Equipment Disinfecting Wipes

Active Ingredients:

0.075% Fifth generation QAC Blend;

0.5% Preservative.

 

Product characteristics:

Vacuum-impregnated; Unfragranced;

Non-corrosive; Non-toxic; Non-staining

Non-caustic; Convenient

 

Recommended Uses:

Healthcare surface disinfection.

Medical Device disinfection.

Disinfection of high-touch items, especially where the use of a spray disinfectant is inadvisable.

 

Instructions for use:

To begin: Remove the lid & remove the sealed in­ner bag. Ensure that the leading wipe is at the top, cut open the bag & place it back in the tub. Open the flap in the lid & pull the leading wipe slowly through the hole. Replace the lid onto the tub and the wipes are ready to use.  When needed: Simply pull out a wipe, tear it off on the perforation and use. Best results are achieved when used on a visibly clean, dry surface. Allow the contact time of your required efficacy, (as per the efficacy table below right), before using the surface again. Repeat as often as required by your Infection Control protocol (suggested proto­cols available on request). Always ensure that the flap is tightly shut after use to prevent drying out of the wipes. Wipe material is not efficiently biodegradable.

 

Pre-Requirements:

None strictly necessary, however OHSA requires the use of eye protection & good ventilation when mixing, handling or discarding chemical disinfectants.

 

Product Description:

Available sizes: 100s Tub; 100s Refill (Wipe Size: 200mm x 140mm)

Dilution Factor: Not applicable - pre-impregnated wipe

Physical Form: White, non-woven wipe

Odour: Mild chemical fragrance

pH: 5-6.5

Risk Classification: B / II

GMDN Code: 58077

GMDN Descriptor:

Medical Device Disinfection Wipe

NRCS Reg. no.: ACT5GNR529/242613/040/0256

Medical Device Reg. No.: Pending

Incompatibility: Anionic detergents, Natural Soaps, Strong oxidisers

STESW4